Several districts are known to be quake-prone, and it is well known that quakes can be devastating or cause extensive damage. Icon offers a specialised product suited to handling a quake shock.
Its chemical composition is so chosen that it can elongate about 18% and even up to 25% during an earthquake. This gives enough signal and time for evacuation in the case of a severe quake. Importantly, engineers appreciate that the construction project can consume less steel, and that translates to more savings.
Chemical composition of ICON |
|||||
| Element | ICON 500 | IS-1786 : 2008 | |||
| % C | 0.15 to 0.22 | 0.25 max. | |||
| % S | 0.035 max. | 0.040 max. | |||
| % P | 0.035 max | 0.040 max. | |||
| % S+P | 0.070 max | 0.075 max. | |||
Dia of Mandrel For Re-Bending |
|||||
| Size of Bar (in mm) | IS 1786: 2008 (Grade Fe-500 D) | ICON 500 D |
|||
| 8 | 4ɸ | 3ɸ | |||
| 10 | 4ɸ | 3ɸ | |||
| 12 | 6ɸ | 4ɸ | |||
| 16 | 6ɸ | 4ɸ | |||
| 20 | 6ɸ | 4ɸ | |||
| 25 | 6ɸ | 4ɸ | |||
| 28 | 6ɸ | 4ɸ | |||
| 32 | 6ɸ | 4ɸ | |||
ɸ = Diameter Of The Test Piece ( Bar in mm ) |
|||||
Dia of Mandrel For Bending |
|||||
| Size of Bar (in mm) | IS 1786: 2008 (Grade Fe-500 D) | ICON 500 D |
|||
| 8 | 3ɸ | 2ɸ | |||
| 10 | 3ɸ | 2ɸ | |||
| 12 | 3ɸ | 2ɸ | |||
| 16 | 3ɸ | 2ɸ | |||
| 20 | 3ɸ | 2ɸ | |||
| 25 | 4ɸ | 3ɸ | |||
| 28 | 4ɸ | 3ɸ | |||
| 32 | 4ɸ | 3ɸ | |||
ɸ = Diameter Of The Test Piece ( Bar in mm ) |
|||||